Electrical Engineering

Safe electrical systems aligned with SBC 401 & SEC

Detailed electrical load schedules, main/sub distribution boards, energy-efficient architectural lighting, and low-current building systems ready for Saudi Electricity Company (SEC) and municipal approvals.

Daylight and architectural lighting integration by SA'F Riyadh
Regulatory Compliance MOMRA & Balady Saudi Council of Engineers (SCE) RCRC Guidelines Saudi Building Code (SBC)

Scope of engineering deliverables

Power Distribution & SEC Coordination

Demand factor calculations, main distribution boards (MDBs), breaker coordination, and SEC substation/meter room allocations.

  • Voltage drop & short-circuit calculations
  • Load balancing across three-phase panels
  • EV charger & solar PV feeder readiness

Architectural Lighting & SBC 602

Task and ambient lighting layouts maintaining strict Watts-per-sqm energy limits under SBC 602 without under-lighting key spaces.

  • DALI / smart dimming scene grouping
  • Exterior facade & landscape IP65 circuits
  • Emergency & exit lighting for commercial projects

Low-Current, Fire Alarm & Security

Integrated fiber backbone, structured CAT6A data, CCTV coverage, access control, and Civil Defense fire detection wiring.

  • KNX / smart automation bus routing
  • Voice/data racks & Wi-Fi AP ceiling drops
  • Addressable fire alarm loop drawings

Electrical Design Checklist Before Construction

Phase / CodeTechnical DeliverableApproval Impact
Power Load ScheduleBalanced phases, spare breaker capacity, and SEC connection kVA ratingPrevents panel tripping & utility delays
SBC 602 Energy AuditHigh-efficacy LED fixture schedule & occupancy sensor zonesMandatory for municipal permit approval
Low-Current IntegrationDedicated conduits separated from high-voltage feedsZero electromagnetic interference

Frequently asked questions

Do your electrical packages satisfy Saudi Electricity Company (SEC) requirements?
Yes. All load schedules, earthing diagrams, meter enclosure details, and cable sizing follow SBC 401 and SEC connection standards.
Can smart home automation be integrated at design stage?
Preparing deep neutral boxes, centralized control risers, and data cabling inside the initial electrical drawings costs a fraction of retrofitting after plastering.

Need a fixed-scope proposal for Electrical Engineering?

Share your building load brief or architectural floor plans below or via WhatsApp for an SBC 401 electrical design proposal.